2350 Industrial Road, Sapulpa, OK 74066 • Main: 918-445-1141 • sales@weamco.com Bulletin FY-112 Toll Free: 800-331-3790 • Fax: 918-445-4617 • www.weamco.com 5-19 Y Strainers LINE SIZE (IN.) OD TYPE FYW (W-W) TYPE FYF (F-F) L BLOWDOWN (NPT) LINE SIZE (IN.) 4 4 1/2 18 1/2 26 12 3/4 4 6 6 5/8 20 1/4 30 16 3/4 6 8 8 5/8 26 37 20 1 8 10 10 3/4 33 1/2 46 23 1 10 12 12 3/4 38 1/4 51 26 1 1/2 12 14 14 42 1/2 56 29 1 1/2 14 16 16 47 1/2 62 32 1 1/2 16 18 18 53 68 36 1 1/2 18 20 20 57 1/2 73 39 2 20 24 24 63 1/2 80 43 2 24 W-W L F-F L 4 5 ° 4 5 ° W-W L F-F L 4 5 ° 4 5 ° TYPE FYW (Weld End) TYPE FYF (Flanged End) •  All dimensions are in inches and based on an ASME flanged closure •  Dimensions shown are good through 600# ASME •  Standard design is based on ASME B31.4 •  Many quick opening closure options are available (see Bulletin OA-112) •  Open area ratios are based on using a 40% open area basket media (see Bulletin AC-112) •  Larger line sizes and custom designs are available Minimum Information Required for RFQ (see Strainer Bulletins SD-118 and SI-112 for assistance) 1. Quantity 2. Line size & ASME flange rating 3. Weamco type 4. Housing pipe schedule 5. Piping design code (ASME B31.4 is standard) 6. Basket media size (see Bulletin AC-112) 7. Housing and basket material (carbon steel is standard) 8. Other special requirements or specifications (paint, etc)